Carbon Monoxide Smoke Detector
Recall Summary Extralink is recalling battery-powered carbon monoxide and smoke detectors because they don't detect carbon monoxide effectively enough, which means people could be exposed to dangerous CO levels while believing their detector is working properly. This detector doesn't meet European safety standards. The recall affects products distributed in Poland.
- Recalling firm
- Extralink
- Product
- Carbon monoxide and smoke detector, battery powered (3 x1,5 V AA). Carbon Monoxide Smoke Detector
- Reason
- The product is not sufficiently sensitive with respect to detection of carbon monoxide (CO) and poses a risk of CO poisoning in that a person may inadvertently be exposed to CO trusting that the product functions correctly. This may lead to asphyxiation. The product does not comply with the General Product Safety Regulation nor with the European standard EN 50291-1.
- Classification
- Class I
- Category
- consumer product recall
- Country
- European Union
- Agency
- SAFETY-GATE
- Recall date
- 2026-04-17
- Status
- Ongoing
- Areas affected
- PL
- Distribution
- Poland
Official recall notice from SAFETY-GATE
Recall details on Nibble Recalls: https://trynibble.app/recalls/4599c6cc-efb7-4076-a1a1-93f7c57a6341